- AutorIn
- Tang Li
- Maik Kahnt
- Thomas L. Sheppard
- Runqing Yang
- Ken V. Falch
- Roman Zvagelsky
- Pablo Villanueva-Perez
- Martin Wegener
- Mikhail Lyubomirskiy
- Titel
- X-Ray Multibeam Ptychography at up to 20 keV
- Untertitel
- Nano-Lithography Enhances X-Ray Nano-Imaging
- Zitierfähige Url:
- https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa2-1032704
- Quellenangabe
- Advanced Science
Erscheinungsjahr: 2024
Jahrgang: 11
Heft: 30
E-ISSN: 2198-3844
Artikelnummer: 2310075 - Erstveröffentlichung
- 2024
- Abstract (EN)
- Hard X-rays are needed for non-destructive nano-imaging of solid matter. Synchrotron radiation facilities (SRF) provide the highest-quality images with single-digit nm resolution using advanced techniques such as X-ray ptychography. However, the resolution or field of view is ultimately constrained by the available coherent flux. To address this, the beam's incoherent fraction can be exploited using multiple parallel beams in an X-ray multibeam ptychography (MBP) approach. This expands the domain of X-ray ptychography to larger samples or more rapid measurements. Both qualities favor the study of complex composite or functional samples, such as catalysts, energy materials, or electronic devices. The challenge of performing ptychography at high energy and with many parallel beams must be overcome to extract the full advantages for extended samples while minimizing beam attenuation. Here, that challenge is overcome by creating a lens array using cutting-edge laser printing technology and applying it to perform scanning with MBP with up to 12 beams and at photon energies of 13 and 20 keV. This exceeds the measurement limits of conventional hard X-ray ptychography without compromising image quality for various samples: Siemens star test pattern, Ni/Al2O3 catalyst, microchip, and gold nano-crystal clusters.
- Andere Ausgabe
- Erstveröffentlichung
DOI: 10.1002/advs.202310075 - Freie Schlagwörter (EN)
- lens-less imaging, microscopy, nano-lithography, ptychography
- Klassifikation (DDC)
- 620
- 500
- Verlag
- Wiley-VCH GmbH, Weinheim
- Förder- / Projektangaben
- Deutsche Forschungsgemeinschaft (DFG)
Chemische Bildgebung von strukturierten Katalysatoren mittels hochauflösender Röntgenmikroskopie in 2D und 3D (C03)
ID: 426888090 - Version / Begutachtungsstatus
- publizierte Version / Verlagsversion
- URN Qucosa
- urn:nbn:de:bsz:15-qucosa2-1032704
- Veröffentlichungsdatum Qucosa
- 20.03.2026
- Dokumenttyp
- Artikel
- Sprache des Dokumentes
- Englisch
- Lizenz / Rechtehinweis
CC BY 4.0