- AutorIn
- Marc Schargus
- Theresa Theilig
- Matus Rehak
- Catharina Busch
- Caroline Bormann
- Jan Darius Unterlauft
- Titel
- Outcome of a single XEN microstent implant for glaucoma patients with different types of glaucoma
- Zitierfähige Url:
- https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa2-783492
- Quellenangabe
- BMC Ophthalmology
Erscheinungsjahr: 2020
Jahrgang: 20
E-ISSN: 1471-2415
Artikelnummer: 20:490 - Erstveröffentlichung
- 2020
- Abstract (EN)
- Background: The aim of this retrospective study was to compare the efficacy and safety profile of a single XEN-microstent in different types of primary and secondary open angle glaucoma. Methods: A single XEN microstent was implanted in patients with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG), pseudoexfoliation glaucoma (PEX) and secondary glaucoma (Sec.Gl). The intraocular pressure (IOP), the active substances of the applied IOP-lowering drugs, the best corrected visual acuity (BCVA) and the mean deviation (MD) of the perimetry were measured at baseline and at regular follow-ups, scheduled at 2 days and 1, 3, 6 and 12 months after surgery. Results: 153 eyes were included in this analysis. 113 eyes were affected by POAG (74%), 5 eyes by NTG (3%), 22 eyes by PEX (14%) and 13 eyes by Sec. Gl (9%). Mean IOP decreased in all treatment groups during the 12 months of follow-up (complete group: 23.9 ± 7.4 to 15.4 ± 5.1 mmHg (p < 0.01); POAG: 22.8 ± 6.5 to 15.1 ± 4.6 mmHg (p < 0.01); NTG: 16.6 ± 3.4 to 11.6 ± 2.2 mmHg (p < 0.05); PEX: 28.0 ± 7.9 to 17.1 ± 6.6 mmHg (p < 0.01); Sec.Gl: 28.9 ± 13.9 to 15.5 ± 6.9 mmHg (p < 0.05)). In the 153 eyes the average number of IOP-lowering drugs applied decreased from 2.6 ± 1.2 to 0.8 ± 1.3 12 months after surgery (p < 0.01). BCVA and mean deviation of automated standard perimetry remained stable in all groups during follow-up. Conclusion: As in eyes suffering from POAG, IOP and number of IOP-lowering drugs applied can be effectively reduced by XEN implantation in eyes suffering from NTG, PEX and secondary glaucoma while leaving BCVA and visual field unchanged.
- Andere Ausgabe
- Link zur Originalveröffentlichung in BMC Ophthalmology
DOI: 10.1186/s12886-020-01764-8
Link: https://doi.org/10.1186/s12886-020-01764-8 - Freie Schlagwörter (EN)
- primary open-angle glaucoma, trabeculectomy, XEN, MIGS
- Klassifikation (DDC)
- 610
- Verlag
- BMC, London
- Version / Begutachtungsstatus
- publizierte Version / Verlagsversion
- URN Qucosa
- urn:nbn:de:bsz:15-qucosa2-783492
- Veröffentlichungsdatum Qucosa
- 07.03.2022
- Dokumenttyp
- Artikel
- Sprache des Dokumentes
- Englisch
- Lizenz / Rechtehinweis
CC BY 4.0